TEST/DIAGNOSTIC PROCEDURES
(Continued)
SOLENOID TEST.
1. (From Lamp Test) Using AUTO-UP, press ADVANCE. Observe that the Player 1 and 2 displays
show the message, COIL TEST, the Player 3 display shows 05 (Solenoid Test identifier). Next,
the Player 3 display shows a series of test steps from 01 through 22, while the Player 1 and 2
displays show the solenoid/circuit name. During each of these steps, pulsing of the respective
solenoid/circuit occurs. The test cycles repeatedly, unless halted via the MANUAL-DOWN
switch. Refer to the Solenoid Table for solenoid numbers and wiring information.
CPU
Board connections at 1P11, 1P12, and 1P19 are also listed in the table.
To continuously pulse a single solenoid/circuit,
use MANUAL-DOWN.
Press ADVANCE to
sequence through the switched, controlled, and special solenoids.
Use AUTO-UP to resume
test cycling, and to proceed to the next test.
EARTHSHAKER
Solenoid Table
Sol.
Wire 1
Connections
Driver
Solenoid Part Number
Function
Solenoid
Playfleldl
Flaahlamp Type
No.
Type
Color
CPU Bd
Cablne,
Trnatr
d_ Dlsplav Bd: p-Plavfield
01A3 Outhole Kicker
Switched {Vla-Brn } 1P11-1
5J1-9: 5J4-9 (A)
033 AE-23-800
01C 3 Captive BallFlashers
Switched
Blk-Brn (Gry-Brn)
5J5-9 (C)
033 #89 flash lamp
Ip
02A 3 Ball Release (Shtr Lane Feeder) Switched {VIO-Re~ 1P11-3
5J1-7: 5J4-8 (A)
025 AE-23-800
02C3 Cntr Ramp 1 & Bldg Flashers
Switched Blk-Red (Gry-RecJ:
5J5-8 (C)
025
#906/#89
flash lamps
2p
03A 3 3-Bank Dr Tgt Reset
Switched {VIa-Om}
1P11-4
5J1-S: 5J4-7 (A)
032 AE-2S-1200
03C 3 Cntr Ramp 2 & Spinner Flashers Switched Blk-Orn (Gry-Orn)
5J5-7(C)
032
#906/#89
flash lamps
2p
04A3 California Fauh
Switched {Via- Vel} 1P11-5
6J1-6: 5J4-S (A)
024 AE-23-800
04C 3 Cntr Ramp 3 Flasher
Switched
Blk-Vel
(Gry-VeI)
5J5-5 (C)
024 #9OS flash lamp
Ip
05A3 Eject Hole
Switched {Vlo-Gm}
1P11-S 5J1-4: 5J4-6 (A)
031 AE-2S-1600
05C3 Cntr Ramp 4 Rasher
Switched
Blk-Gm (Gry-Gm)
5J5-4 (C)
031 #906 flashlamp
Ip
06A 3 Bottom Ball Popper
Switched {VIO-BIU}
1P11-7
5J1-3: 5J4-4 (A)
023 AE-23-800
06C3 Right Ramp 1 Flasher
Switched
Blk-Blu (Gry-Blu)
5J5-3(C)
023 #906 flash lamp
Ip
07A 3 Knocker
Switched {Vla-Blk}
1P11-8
5J1-2: 5J4-2 (A)
030 AE-23-800
07C3 Right Ramp 2 Flasher
Switched
Blk-Vlo (Gry-VIo)
5J5-2 (C)
030 #906 flash lamp
Ip
08A3 Not Used
Switched {Vlo-Gry}
1P11-9
5J1-1: 5J4-1 (A)
022
08C3 Right Ramp 3 Flashers
Switched
Blk-Gry (Gry-Blk)
5J5-1 (C)
022
#906/#89
flash lamps
2p
09 Not Used
Controlled Bm-Blk 1P12-1 5J2-9: 5J6-9: 2J4-3
017
10 Upper Playfleld Gnl ilium Relay Controlled Bm-Red 1P12-2 5J2-8: 5J6-8: 2J4-5
09 6580-12145-01
4
: b
11 lnsert Board Gnl ilium Relay
Controlled Bm-Orn 1P12-4 5J2-S: 5J6-7: 2J4-6
016 5580-09555-01
12 AlC Select Relay
Controlled Bm-Vel
1P12-5
5J2-5
08 6580-09555-01 5
13 Top Ball Popper
Controlled Brn-Grn 1P12-6
5J2-4: 5J6-6
015 AE-23-800
14 Jackpot Flasher
Controlled Bm-Blu 1P12-7
5J2-4: 5J6-3
07 #906 flashlamps4a
2p
15 Low Playfleld Gnl IIIlum Relay
Controlled Brn-Vlo 1P12-8
5J2-2: 5J6-2
014 5680-12145-01
16 On Ramp & J Bumper Flashers Controlled Bm-Gry 1P12-9
5J2-1: 5J6-1
06
#906/#89
flash lamps
2p
17 Leh Jet Bumper
Spedal #1 Blu-Brn 1P19-7
5J3-7: 5J7-7
075 AE-23-800
18 Left Kicker ('sllng')
Special #2 Blu-Red 1P19-4
5J3-6: 5J7-6
071 AE-26-1500
19"
Right Jet Bumper
Spedal #3 Blu-Orn 1P19-3
5J3-3: 5J7-3
073 AE-23-800
20 Right Kicker ('sllng')
Special #4 Blu-Vel
1P19-6
5J3-4: 5J7-5
069 AE-26-1500
21 Top Jet Bumper
Special #5 Blu-Gm 1P19-8
5J3-2:5J7-2
077 AE-23-800
22 Ouake Motor
Special #6 Blu-Blk 1P19-9
5J3-1: 5J7-1
079 14-7951
-
Right Flipper
-
Om-Vlo 1P19-1
2J5-5: 2J10-7
-
Lower Right Flipper
[Blu-Vlo) 2
[2J10-1: 2J8-15)
FL
11630/50VDC
-
Left Flipper
-
Om-Gry 1P19-2
2J5-4: 2J10-8
-
Lower Left Flipper
(BIu-Gry) 2
[2J10-2:2J8-4)
FL
11630/50VDC
Upper Left Flipper
[Blk-Blu]
[2J10-4:2J8-12)
FL
11722/60VDC
NllI.!:l;. I. Wire colors. except flipper Om- Vio and Om-Ory. are ground connections (to coil terminal with unbanded end of diode). Flipper Om- Vio and
Om-Gry wires connect from
CPU
Board to flJpper switch. 2. Flipper connections shown in braces are from flipper switch to flipper coil. 3. "A"
circuits are pulsed. when Sol. 12 is de-energized; "C" circuits are pulsed. with Sol. 12 energized. Wire colors in brackets are those from respective A
and C terminals corresponding to the J1-terminal connection listed for the Aux Power Driver
Bd,
which controls the device pulsing by Sol. 12.
4. Relay i. mounted on Relay
Bd,
(48) pin C-l199g-l; (4b) Cl1902-I.
S.
Relay is mounted on Aux Power Driver
Bd,
0-12247 in the backbox.
EARTHSHAKER 30