A To reach Game-Over Mode, use AUTO-UPand press
ADVANCEonce.
DR
DUDE
now goes to the Game-Over Mode.
B. To clear the coinage audits (Au01 through 04) select (via the Start
button) the YES option, as shown in the player 3/4 display. This
adjustment zeroes the counters tallying the number of coins through
each slot, the Paid Credits counter, and the Credits display.
Details of Adjustment Items 01 through 70
A
01
Auto Replay (or Fixed Replay)
Of the two options, AUTOREPLAYis the percentage of replays automatically
awarded per game. The game program aids a pinball's initial installation by
causing a comparison of the value of the Replay Level to the value of all players'
scores every 50 games. At each comparison, the program increases (or decreases)
the Replay Level by an amount necessary to achieve the replay percentage specified
either via the factory setting or later operator selection. Use the Start button to
change the percentage within the range of 5 to 25
(%).
with the value increasing
using AUTO-UP(or decreasing using MANUAL-DOWN).The next Start button
change below 5%, selects the FIXEDREPlAY option.
For AUTOREPLAY,Ad 02 provides the Starting Replay Level (Player 1 and 2
displays show REPLAYSTART). Ad 03 provides the number of replay levels
(0I, 02, 03, or 04). DR.
DUDE
then proceeds to Ad 06 automatically.
For FIXEDREPLAY,Ad 02 is the first replay level (REPlAYLEVEL 1). Ad 03,04,
and 05 are the other replay levels.
A
02 StartingReplay Level (or Replay Levell)
For AUTOREPLAY(refer to Ad 01), the initial Factory Setting is listed in the
Game Adjustment Table. The range of settings is 1,000,000 through 9,800,000 (by
increments of 100,000 with Auro-UP or decrements of 100,000 with MANUAL-
DOWN).
For FIXEDREPLAY,the operator can enter the value to be used for the first fixed
replay score level via the Start button. The range of settings is: OFF; 100,000
through 9,900,000 (by increments of 100,000 with Auro-UP, or decrements of
100,000 with MANUAL-DOWN).
• 03 Replay Levels (or Replay Level
2)
For AUTOREPLAY(refer to Ad 01), this is the number of replay levels in a game.
The option range is one, two, three, or four replay level(s). When the operator
chooses two replay levels,
DR.
DUDE
automatically adjusts the second replay level
to be twice the value selected for Ad 02, the starting replay level. Choosing three or
four replay levels automatically adjusts their replay levels to three times or four
times the Ad 02 value.
For FIXEDREPLAY,the technique of value entry and the range of settings are
identical to those of Ad 02.
GameAdjustments 1-15