Page 11 - Whirlwind

Basic HTML Version

\W~~[f~W~lJil@]
GAME STATUS DISPLAYS (Continued)
W[}u~rrijw~lJ'il~
Game Adjustment Table
AdJuatment
D.scrlptlve Phrase
Factory Setting 6
Itam
(Lower)
(Lower)
(Upper Display)
Domestic
WGer/
(US/Can . ) French European
Ad 01
AUTO REPLAY 1
or
10 (%)
FIXED REPLAY 1
SCORES
02
REPLAY START (or REPLAY LEVEL 1) 1
4,600,000
6.000.000
03
REPLAY LEVELS (or REPLAY LEVEL 2) 1
P1 (or OFF)
02
04
(REPLAY LEVEL 3) 1
(see text)
05
(REPLAY LEVEL 4) 1
(see text)
06
REPLAY AWARD
Credit
07
SPECIAL AWARD
Credit
08
MATCH FEATURE
10 % 8% 10%
09
BALLS
I
GAME
03
10
TILT WARNING
03
01
11
MAXIMUM EX. BALL
06
03
12
MAXIMUM CREDITS
10
20
30
13
HIGHEST SCORES
On
14
BACKUP HI. SCA .1
6,000,000
8.000.000
15
BACKUP HI. SCA. 2
5,500,000
7.500.000
16
BACKUP HI. SCA. 3
5,000,000
7.000.000
17
BACKUP HI. SCA. 4
4,500,000
6.500.000
18
HI. SCR .1 CREDITS
01
03
01
19
HI. SCR.2 CREDITS
01
01
00
20
HI. SCR .3 CREDITS
01
01
00
21
HI. SCR.4 CREDITS
01
01
00
22
H. S. RESET EVERY
3,000
1.000
23
FREE PLAY
NO
24
U.S.A. 2 COINAGE (4 COINS 3 PLAYS) 2,3,4
USA 2 French 1 German 2
25
LEFT UNITS
03
02
06
26
CENTER UNITS
12
10
12
27
RIGHT UNITS
03
20
30
28
UNITS! CREDIT
04
05
05
29
UNITSI BONUS
00
20
00
30
MINIMUM UNITS
00
00
00
31·58
Gama.specific Play
I
Coinage Adjustments (detailed in text, the Game·speclfic
Adjustments Setting Table and the Difficulty Setting Comparison Table)
59
5
INSTALL ADDABALL
NO
5
60 5 INSTALL 5·BALL
NO
61
INSTALL NOVELTY
NO
62
5 INSTALL EX. EASY
NO
5
63 5
INSTALL EASY
NO
64
INSTALL MEDIUM
NO
65 5 INSTALL HARD
NO
66
5 INSTALL EX. HARD
NO
67
AUTO BURN-IN
NO
68
CLEAR COINS
NO
69
CLEAR AUDITS
NO
70
INSTALL FACTORY
NO
NOTES:
1 . Aytomatic Replay percentage value range is adjustable from 5 to 25%, via the Credit Button. Item 02
permits changing the factory setting value for Replay Start Level (valid for next 50 games played).
Item 03 permits setting up to four replay levels, with values as detailed in text describing Item 03.
For Fixed Replay Scores, set Auto Replay value to 1 less than 5(%) via the Credit Button. Go to items
02 , 03, 04, and 05; install their replay level scores .Turn off any replay level by setting 00 as its value.
2. Phrase in parentheses is Factory Setting Phrase appears in player displays. Press Credit Button
to change setting of the game pricing of Item 24.
3. To change country OR coinage setting, press Credit button to -obtain 24 Standard Settings, followed by a
Custom Setting. The Custom Setting activates items'2~ through 30. When a Standard Setting is used,
items 25 through 30 are set automatically, and cannot be changed.
4. Refer to Pricing Table and text describing these items .
5. Special Preset Adjustment, whose effects are noted in the qame Adjustment text .
6. Entries in Factory Setting columns for French and W. German games show only differences from entries