GAME ADJUSTMENT PROCEDURE
(Continued)
Details of Adjustment Items 01 through 70
01 Auto Replay (or Fixed Replay)
Of the two options, AUTO REPLAY is the percentage of replays automatically awarded per game.
The game program aids a pinball's initial installation by causing a comparison of the value of the
Replay Level to the value of all players' scores every 50 games. At each comparison, the program
increases (or decreases) the Replay Level by an amount necessary to achieve the replay
percentage specified either via the factory setting or later operator selection. Use the Credit button
to change the percentage within the range of 5to 25
(%),
with the value increasing using AUTO-UP
(or decreasing using MANUAL-DOWN).
The next Credit button change below 5%, selects the
FIXED REPLAY option.
For AUTO REPLAY, Ad 02 provides the Starting Replay Level (the upper display shows REPLAY
START).
Ad 03 provides the number of replay levels (01, 02, 03, or 04).
®t!':I@ ©t!':In
then
proceeds to Ad
06
automatically.
For FIXED REPLAY, Ad 02 is the first replay level (REPLAY LEVEL 1). Ad 03, 04, and 05 are the
other replay levels.
02 Stanlng Replay Level (or Replay Level 1)
For AUTO REPLAY (refer to Ad
01),
the initial Factory Setting is listed in the Game Adjustment
Table. The range of settings is
800,000
through
9,800, 000
(by increments of
100,000
with AUTO-
UP or decrements of
100,000
with MANUAL- DOWN).
For FIXED REPLAY, the operator can enter the value to be used for the first fixed replay score level
via the Credit button.
The range of settings is:
OFF; 100,000
through
9.900, 000
(by increments
of
100,000
with AUTO-UP, or decrements of
100,000
with MANUAL-DOWN).
03
Replay
Levels
(or Replay
Level
2)
For AUTO REPLAY (refer to Ad
01),
this is the number of replay levels in a game. The option range
is
one, two, three, or four
replay level(s). When the operator chooses two replay levels,
IIDt!':I®
©tt.\iroi
automatically adjusts the second replay level to be twice the value selected for Ad
02,
the starling
replay level. Choosing three or four replay levels automatically adjusts their replay levels to three
times or four times the Ad 02 value.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to those of
Ad 02.
04
(Replay Level 3)
For AUTO REPLAY, this Adjustment Item is not applicable.
®~IW
©t!':I'U'8
automatically bypasses this
adjustment.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to those of
Ad 02.
05
(Replay
Level 4)
For AUTO REPLAY, this Adjustment Item is not applicable.
1!ltt.\1D)
©~'ii'3automatically bypasses this
adjustment.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to those of
Ad