U.6 Set Game I.D.
This utility allows the operator to install a message, such as game location, that only
appears on printouts. Press the Enter button to activate Set Game I.D.. Use the Up or
Down button to rotate letters. Use the Start button to rotate punctuation marks, (if
desired). Press the Enter button to lock in the desired letter and punctuation.
U.7 Factory Adjustment
Press the Enter button to restore the adjustments to factory settings, then press the Up
button to display the next utility.
U.S Factory Reset
Press the Enter button to restore the adjustments to their factory setting, clear the
Audits, H.S.T.D Table, and Custom Message/Game I.D. Press the Up button to display
the next utility.
Factory SetUng Ta
e
Adj#
Adj Description
U.S.A.
German
French
European
A109
Replay Level
1
75,000,000
85,000,000
85,000,000
85,000,000
A113
Replay Boost
7,000,000
7,000,000
7,000,000
7,000,000
A410
Backup Champion
200,000,000 250.000.000 250,000.000 250,000,000
A4 11
Backup H.S .T.D.
1
150,000,000 175,000,000 175,000,000 175,000,000
A412
Backup H.S.T .D.
2
125,000,000 150,000,000 150,000,000 150,000,000
A413
Backup H.S.T.D. 3
100,000,000 125,000,000 125,000,000 125,000,000
A414
Backup H.S.T.D. 4
75,000,000
100,000,000 100.000,000 100,000,000
i
bI
U.9 Presets
Press the Enter button to activate the Presets Group. Use the Up or Down buttons to
cycle through the available Presets. When the desired Preset is displayed, press the
Enter button to lock in that Preset. If you realize you have made a mistake, press the
Escape button while "Saving Adjustment Value" is displayed. The new value is
ignored and the original value is retained.
U.9
01 Install Extra Easy
The operator can change the game play difficulty adjustments to a combination
that is MUCH LESS difficult than the Factory Settings. The Game Difficulty
Setting Table lists the adjustments and the settings that comprise the 'Extra
Easy' Group.
U.9
02
Install Easy
The operator can change the game play difficulty adjustments to a combination
that is somewhat LESS difficult than the Factory Settings. The Game Difficulty
Setting Table lists the adjustments and the settings that comprise the 'Easy'
Group.
U.9
00
Install Medium
The operator can change the game play difficulty adjustments to a combination
that is about the SAME difficulty as the Factory Settings. The Game Difficulty
Setting Table lists the adjustments and settings that comprise the 'Medium'
Group.
U.9
Install Hard
The Getaway 1-19