Page 30 - Star Wars Episode I

Basic HTML Version

FEATURE ADJUSTMENTS CONTINUED•..
GUNGAN Memory
This can enable the memory feature on the GUNGAN spellout (in the jets) causing it to
NOT reset between balls.
Settings: Yes, No
Factory Setting: No (Reset between bails.)
Attract Mode Sounds
When set to yes, the flipper and Start buttons will make sounds when pressed in the
Attract mode. If this adjustment is set to no, then the buttons will never make sounds.
Settings:
Yes or No
Factory Setting: Yes
Note: Even when set to yes, after
a
few presses, these buttons will make no sounds for
about two minutes.
Attract Mode Music
When set to yes, this game will briefly play music periodically in the Attract mode.
Settings:
Yes or No
Factory Setting: No
Neon Warm-up Time (minutes)
Some tubes have a gas that's an argon/mercury mixture. When it is turned on, the
mercury gives off a lot of UV, which is transformed into visible light by the phosphorus
coating on the inside of the tube.
If the tube is left off for a long time, the mercury cools; this means that when the tube is
next turned on, there will be some dull spots, as the mercury is not giving as much UV.
Note: The dull spots do not affect the operation or safety of the neon tube or the game in
any way. It is purely cosmetic.
This adjustment sets the time (in minutes) that the tube will be turned on in the Attract
mode so that it stays warm and looking good.
Settings:
0 to 120 minutes (2 hours)
Factory Setting: 5 minutes
Neon Run Time (minutes)
Some tubes have a gas that's an argon/mercury mixture. When it is turned on, the
mercury gives off a lot of UV, which is transformed into visible light by the phosphorus
coating on the inside of the tUbe.
If the tube is left off for a long time, the mercury cools; this means that when the tube is
next turned on, there will be some dull spots, as the mercury is not giving off as much
UV. The tube will be turned on in the Attract mode so that it stays warm and looking
good.
Note: The dull spots do
not
affect the operation or safety of the neon tube or the game in
any way. It is purely cosmetic.
This adjustment sets the run time (in minutes). The run time is the time between warm-
ups. During this time the neon tube will be cycled with the Attract mode lamp effects.
Settings:
5 to 300
Factory Setting: 60 (1 hour)
1-22