GAME ADJUSTMENT PROCEDURE
(Continued)
63
Install
Easy
The operator can change the game play difficulty adjustments to a combination that is slightly easier than
the Factory Settings. Individual Adjustments are affected, as follows:
M.
~
~~ltl
S~lliog
M.
~
~~ltl
S!:llling
31 Lock Memory
Yes
39 Power Kick Safety
On
32 Time Lock
Easy
40 Power Kick Memory Yes
33 Bonus Holdover Time 11 sec
41 Consol. Extra Ball
Yes
34 Detour Exit Memory Yes
42 Extra Ball Memory
Yes
35 Detour Advance
50,000
43 Special Memory
Yes
36 Target Memory
Yes
46 Power Kick Initial
Yes
37 Light Extra Ball
3rd
47 Mega-Score Value
200,000
38 Timelock Extra Ball
20 sec
48 Mega-Score Shots
50
64
Install Medium
The operator can change the game play difficulty adjustments to a combination that matches the Factory
Settings. Individual Adjustments are affected, as follows:
M.
~
~!.i!ltl S!.i!ltiOg
M.
~
t::l!i!W~etling
31 Lock Memory
Yes
39 Power Kick Safety
On
32 Time Lock
Regular
40 Power Kick Memory Yes
33 Bonus Holdover Time 10 sec
41 Consol. Extra Ball
Yes
34 Detour Exit Memory Yes
42 Extra Ball Memory
No
35 Detour Advance
50,000
43 Special Memory
No
36 Target Memory
Yes
46 Power Kick Initial
Yes
37 Light Extra Ball
3rd
47 Mega-Score Value
150,000
38 Timelock Extra Ball
17 sec
48 Mega-Score Shots
50
65
Install
Hard
The operator can change the game play difficulty adjustments to a combination that is more difficult than
the Factory Settings. Individual Adjustments are affected, as follows:
M.
~
~!.i!ltl ~!.i!lliOg
M.
~
t::l!i!ltl~!i!tting
31 Lock Memory
Yes
39 Power Kick Safety
On
32 Time Lock
Hard
40 Power Kick Memory No
33 Bonus Holdover Time 8 sec
41 Consol. Extra Ball
No
34 Detour Exit Memory No
42 Extra Ball Memory
Yes
35 Detour Advance
30,000 .
43 Special Memory
Yes
36 Target Memory
Yes
46 Power Kick Initial
No
37 Light Extra Ball
3rd
47 Mega-Score Value
100,000
38 Timelock Extra Ball
17 sec
48 Mega-Score Shots
20
66
Install Extra Hard
The operator can change the game play difficulty adjustments to a combination that is much more difficult
than the Factory Settings. Individual Adjustments are affected, as follows:
M.
~
~!:lltl S!:llliOg
M.
~
~!:lltl ~!:llting
31 Lock Memory
No
39 Power Kick Safety
Off
32 Time Lock
Hard
40 Power Kick Memory No
33 Bonus Holdover Time 7 sec
41 Consol. Extra Ball
No
34 Detour Exit Memory No
42 Extra Ball Memory
No
35 Detour Advance
20,000
43 Special Memory
No
36 Target Memory
No
46 Power Kick Initial
No
37 Light Extra Ball
4th
47 Mega-Score Value
50,000
38 Timelock Extra Ball
15 sec
48 Mega-Score Shots
10
67
Auto Burn-W:1
The operator can choose the YES option for this Special Preset Adjustment to perform certain automatic
testing of the game, as used in the factory. It does not affect the game operation, but merely provides for
a cyclic testing of most of the game's mechanisms.
ltoa~ lUngs 19