GAME ADJUSTMENT PROCEDURE
(Continued)
Details of Adjustment
Items 01 through 70
01 Auto Replay (or Fixed Replay)
Of the two options, AUTO REPLAY is the percentage of replays automatically awarded per
game. The game program aids a pinball's initial installation by causing a comparison ot the value
of the Replay Level to the value of all players' scores every 50 games. At each comparison, the
program increases (or decreases) the Replay Level by an amount necessary to achieve the
replay percentage specified either via the factory setting or later operator selection.
Use the
Credit button to change the percentage within the range of 5 to 25 (%), with the value
increasing using AUTO-UP (or decreasing using MANUAL-DOWN).
The next Credit button
change below 5%, selects the FIXED REPLAY option.
For AUTO RE PLA Y, Ad 02 provides the Starting Replay Level (Player 1 and 2 displays show
REPLA Y START). Ad 03 provides the number of replay levels (01, 02, 03, or 04). JOKERZ
then proceeds to Ad 06 automatically.
For FIXED REPLAY, Ad 02 is the first replay level (REPLAY LEVEL 1). Ad 03, 04, and 05 are
the other replay levels.
02
Starting Replay Level
(or Replay Level
1)
For AUTO REPLAY (refer to Ad 01), the initial Factory Setting is listed in the Game Adjustment
Table. The range of settings is
800,000
through
9,800.000
(by increments of 100,000 with
AUTO-UP or decrements of 100,000 with MANUAL- DOWN).
For FIXED REPLAY, the operator can enter the value to be used for the first fixed replay score
level via the Credit button.
The range of settings is:
OFF; 100,000
through
9,900,000
(by
increments of 100,000 with AUTO-UP, or decrements of 100,000 with MANUAL-DOWN).
03 Replay Levels (or Replay Level
2)
For AUTO REPLAY (refer to Ad 01). this is the number of replay levels in a game. The option
range is
one, two, three, or four
replay level(s). When the operator chooses two replay levels,
JOKERZ automatically adjusts the second replay level to be twice the value selected for Ad 02,
the starting replay level. Choosing three or four replay levels automatically adjusts their replay
levels to three times or four times the Ad 02 value.
For FIXED REP LAY, the technique of value entry and the range of settings are identical to
those of Ad 02.
04 (Replay Level
3)
For AUTO REPLAY, this Adjustment Item is not applicable. JOKERZ automatically bypasses
this adjustment.
For FIXED REP LAY, the technique of value entry and the range of settings are identical to
those of Ad 02.
05 (Replay Level
4)
For AUTO REPLAY, this Adjustment Item is not applicable. .JOKERZ automatically bypasses
this adjustment.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to
those of Ad 02.