Game Adjustment Procedure
Adjustment Items 01 through 70
The coin door must be open to access the Game Adjustment/Diagnostic switches.
All readings and setting changes require operation of these coin door switches.
Some setting changes utillze the Credit button; Adjustment #49 also uses the
flipper buttons. Additional text describing the game adjustment items follows this
procedure: the value ofthe Factory Setting for each Game Adjustment item is in the
preceding GAME
SHOW
Game Adjustment Table.
1. Use AUTO-UP and press ADVANCE. The Id 00 display initially appears.
Press ADVANCEuntil the Player 3 display indicates Ad 01. If the
factory setting has not changed, the Player 1 and 2 Score displays
indicate AUTOREPIAY, and the Player 4 display shows
l00lb.
indicating a
10% replay percentage. (The game program adjusts itself automatically,
as discussed in the following text concerning the 'details' about
Adjustment Item 01.)
2. To reach a higher item number (in the Player 3 display), use AUTO-UP
and press ADVANCE. To return to a previous item number. use
MANUAL-DOWNand press ADVANCE.
3. With the desired Game Adjustment Item number showing in the Player 3
display. increase the setting value (or select another option) shown in the
Player 4 display by usmg AUTO-UP and pressing the Credit button.
Repeat this step for each item, until all changes to the factory settings for
the Game Adjustment Items have been made. The preceding Game
Adjustment Table consolidates the Factory Settings into one grouping.
(The same procedure can be used for Audit Items. To zero Au 01 - 04
(concerning the coin chutes and the total coins), the operator can
proceed to item 68, Clear Coins. and press the Credit button to obtain
the YES option. The operator then presses the ADVANCEbutton and
notes the "DONE" display, which verifies that the entry values for items
01 through 04 of the Audit Items are now reset to zero.)
For example. the operator may desire to change the degree of game play
difficulty from the Factory Setting (equivalent to the Install Medium (Ad
64) difficulty. along With a number of other automatically installed
settings. as shown in the right column of the Game Adjustment Table) to
another difficulty more suitable for the players at a particular game stte.
Four other 'automatic' play difficulty settings (Ad62 - Ad 66) are
available, each of which, if selected. installs all the adjustments listed for
that difficulty in the Game Adjustment Setting Comparison Table. which
precedes the 'details' text.
4. To proceed rapidly through the entire adjustments series, press and
hold ADVANCE,until Ad 70 shows in the Player 3 display. From item
70, you can: (A)return to the Game-Over Mode; or (B) restore factory
settings and zero audit (bookkeeping) totals. Perform either of the
following. as desired: