Page 28 - Rollergames

Basic HTML Version

70 Clear Coins
The operator can request the clearing of the coinage audits (Au 01 through 04) by selecting (via the START
button) the YES option, as shown in the lower display. This adjustment zeroes the counters tallying the
number of coins through each slot, the Paid Credits counter, and the Credits display. After the YES option
is displayed, the operator must press the ADVANCE button. The game then displays DONE to show that
the coinage audits were reset to zero.
._
GAME ADJUSTMENT PROCEDURE
(Continued)
65 Install Hard
The operator can change the game play difficulty adjustments to a combination that is somewhat more
difficult than the Factory Settings. The Game Difficulty Setting Table, which precedes these 70 individual
Adjustments descriptions, lists the Adjustments and the settings that comprise the 'Hard' group.
66 Install Extra Hard
The operator can change the game play difficulty adjustments to a combination that is much more difficult
than the Factory Settings. The Game Difficulty Setting Table, which precedes these 70 individual
Adjustments descriptions, lists the Adjustments and the settings that comprise the 'Extra Hard' group.
67 Auto Burn-In
The operator can choose the YES option for this Special Preset Adjustment to perform certain automatic
testing of the game, as used in the factory. It does not affect the game operation, but merely provides for
a cyclic testing of most of the game's mechanisms.
68 Install Factory
The operator can request the game (via the START button) to provide the normal Factory Settings,
essentially restoring the game to its 'factory condition'. The operator must select the 'YES' option for this
adjustment to obtain the resetting action. The 'YES' option clears all Audits, resets all Game Adjustments
to the respective Factory Settings, and provides a restart of the Auto Replay (Ad 01). After selecting the
YES option, the operator must press the ADVANCE button. The game then displays the message,
FACTORY SETTING.
Closing of the coin door before appearance of the FACTORY SETTING message or a problem in the
Memory Protect circuit will cause the game to display ADJUST FAILURE. A loss of battery power or
improper treatment of the Game Adjustments will cause the game to attempt to restore Factory Settings.
The game announces the results of this reset process with the appropriate message, FACTORY
SETTING or ADJUST FAILURE.
69 Clear AudIts
The operator can request the clearing of the non-coinage audits (Au 05 through 55) by selecting (via the
START button) the YES option, as shown in the lower display. This Adjustment zeroes the counters
tallying the remaining Audit factors. Please note that this does NOT affect the Automatic Replay Percen-
taging data nor the automatic High Score Reset counter. After the YES option is displayed, the operator
must press the ADVANCE button. The game then displays DONE to show that the non-coinage audits
were reset to zero.