T.4 Solenoid Test
The Solenoid Test has three modes: Repeat, Stop, and Run. Only
one solenoid should pulse at a time. The system has detected a problem if; more then one
solenoid pulses, a solenoid comes On and stays On, or no solenoids pulse during the Repeat
or Run modes.
Repeat
The Repeat Mode pulses a single solenoid. After entering this test, Solenoid 1 shows
in the display. and the corresponding solenoid activates, Press the Up or Down button
to cycle through the solenoids, one at a time. The same solenoid pulses until the Up or
Down button is pressed. Either press the Escape button to return to the Test Menu, or
press the Enter button to advance to the next mode.
Stop
The Stop Mode halts the Solenoid Test. Press Enter during the Repeat mode and the
Solenoid Test Stops.
No solenoids should be activated while the test is stopped.
Either press the Escape button to return to the Test Menu, or the Enter button to
advance to the next mode.
Run
The Run Mode cycles through the solenoids automatically.
The display shows the
name and number of the solenoid currently being pulsed.
Either press the Escape
button to return to the Test Menu, or the Enter button to advance to the next mode.
T.5 Flasher Test
This tests the flashlamp part of the solenoid circuit exclusively.
This,
like the Solenoid Test has three test modes: Repeat, Stop, and Run. During this test, only one
flashlamp circuit should pulse at a time. The system has detected a problem if more than one
circuit pulses, a circuit stays On, or no circuits pulse during the Repeat or Run modes.
Repeat
The Repeat mode pulses a single flashlamp.
After entering this test, the name and
number of the first flashlamp circuit will show in the display and the corresponding
bulb(s) flash. Press the Up or Down button to cycle through all of the flashlamp circuits
one at a time. The same circuit pulses until the Up or Down button is pressed. Either
press the Escape button to return to the Test Menu, or press the Enter button to
advance to the next mode.
Stop
The Stop Mode halts the Flasher Test. No flash lamp circuit should be active during this
mode. Either press the Escape button to return to the Test Menu, or the Enter button
to advance to the next mode.
Run
The Run Mode cycles through the flash lamps automatically.
The display shows the
name and number of the flashlamp circuit currently being pulsed and the
corresponding bulb(s) flash.
Either press the Escape button to return to the Test
Menu, or the Enter button to advance to the next mode.
T.G General Illumination
This test checks all of the General Illumination circuits. There
are two modes of operation: Stop and Run.
Stop
Press the Up or Down buttons to cycle through the General Illumination Test manually.
All illumination is tested first, followed by an individual circuit test. The circuit name and
number will show in the display while the corresponding lamps light. If any other results
occur the system has detected an error.
Run
Press the Enter button any time during Stop mode and the General Illumination Test
cycles through automatically.
For each circuit shown in the displays the corresponding
bulbs should light. If any other results occurs the system has detected a problem.